A-Neuvideo ANI-8PDU-24V Gebrauchsanweisung - Seite 7

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Schalter A-Neuvideo ANI-8PDU-24V herunter. A-Neuvideo ANI-8PDU-24V 12 Seiten. 8-port 24v dc power manager

A-Neuvideo ANI-8PDU-24V Gebrauchsanweisung
A
NEUVIDEO
RS-232 & Telnet Commands
COMMAND
? 8
HELP 8
HELP N1 8
IPCFG 8
IPSTATIC N1 N2 N3 8
IPDHCP N1 8
VERSION 8
FADEFAULT 8
REBOOT 8
PWR N1 N2 8
PWR N1 NAME N2 8
PWR_STATUS N1 8
TEMPERATURE 8
FAN_SET N1 8
FAN_SET N1 N2 N3 8
NOTE: Commands will not be executed unless followed by a carriage return. Commands are not case-sensitive.
DESCRIPTION & PARAMETERS
Show the full command list.
Show the full command list.
Show a description of command N1.
N1 = {Command}
Display the current IP configuration.
Set the full static IP configuration.
N1 = X.X.X.X
[X = 0 ~ 255, IP Address]
N2 = X.X.X.X
[X = 0 ~ 255, Netmask]
N3 = X.X.X.X
[X = 0 ~ 255, Gateway]
Enable or disable DHCP for obtaining the unit's IP configuration.
N1 = ON, OFF
Show the unit's firmware version.
Reset the unit to the factory defaults.
Reboot the unit.
Enable or disable power output N1.
N1 = 1 ~ 8
[Port number]
N2 = ON, OFF
Rename power output N1.
N1 = 1 ~ 8
N2 = {Name String}
Show the current power state (volts, watts, amps) of power output N1.
N1 = 1 ~ 8
[Port number]
Show details of the unit's temperature and fancontrol settings.
Set non-"Auto Mode" fan speed or enable "Fan Auto Mode".
Available values for N1:
0 ~ 100 [Disable Fan Auto Mode and set the fan speed to the selected percentage]
AUTO
[Enable Fan Auto Mode]
Set the fan speed and temperature threshold for the selected automatic speed tier.
Available values for N1:
AUTO_LOW
[Auto fan setting to adjust]
AUTO_MID
AUTO_HIGH
N2 = 0 ~ 100
[Temperature threshold in °C]
N3 = 0 ~ 100
[Fan speed in percent]
5
RS-232 & Telnet Commands
[Port number]
[16 characters max]