Symptom
The freezer temperature is not
sufficient, red light lights up,
temperature alarm sounds
Heavy build up of frost, possi-
bly also on the door seal.
The compressor does not start
immediately after changing
the temperature setting.
If, after carrying out the necessary checks there is still a fault with your
appliance please contact your local AEG Service Force Centre.
In guarantee customers should ensure that the suggested checks have
been made as the engineer will make a charge if the fault is not a mecha-
nical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee service
calls.
Possible Cause
Temperature is not properly
adjusted.
Door was open for an exten-
ded period.
A large quantity of warm
food was placed in the
appliance within the last 24
hours.
The appliance is near a heat
source.
Door seal is not air tight (pos-
sibly after changing over the
hinges).
This is normal, no error has
occurred.
Remedy
Please look in the "Initial Start
Up" section.
Open the door only as long as
necessary.
Press the fast freeze switch
Please look in the "Installation
location" section.
Carefully warm the leaking
sections of the door seal with
a hair dryer (not hotter than
approx. 50 °C). At the same
time shape the warmed door
seal by hand until it sits cor-
rectly.
The compressor starts after a
period of time.
15