2. The activated carbon filter should under absolutely no circum¬
stances ever be washed. To remove it, press the two red
buttons B and pull it down and out (Fig. 14).
3. Clean the inner housing using a hot detergent solution only
(never use caustic detergents, abrasive powders or brushes).
4. Fit the new activated carbon filter in its special frame, inserting
the back end first and then pushing the front into place before
finally locking it into position using the lock devices (red
buttons, Fig. 14, B) on the activated carbon filter (Fig. 14, C).
6. Proceed as follows to reset the filter saturation display (coun¬
ter). Select any fan speed using my |©| E or |®| F buttons and
then press the
|o] B
and [©] F buttons at the same time,
continuing to hold them down for at least 3 seconds until the
flashing letter C stops being shown on the display (D) and then
press the [O] button B.
The activated carbon filter display is now ready for use again.