Kohler 1092607 Service-Kit-Anleitung - Seite 3
Blättern Sie online oder laden Sie pdf Service-Kit-Anleitung für Sanitärprodukt Kohler 1092607 herunter. Kohler 1092607 12 Seiten. Sprayhead and membrane
Replace the Sprayhead
Position the O-ring into the top of the ball joint.
Position the sprayhead and clamp onto the ball joint.
Insert a 1/4" hex wrench into the ball joint.
Turn counterclockwise to tighten.
Verify the sprayhead is tightened down all the way to the ball joint.
Replace the Spray Membrane
Place the spray membrane over the sprayhead with the KOHLER logo
aligned with one of the setscrew holes on the sprayhead.
Press the spray membrane seal into the sprayhead groove by applying
pressure evenly. This will ensure optimum performance.
Place the spray face over the sprayhead, aligning the setscrew holes with
the setscrew in the sprayhead.
Use a 5/64" hex wrench and turn each of the three setscrews
counterclockwise, backing them out, until they are flush with the surface
of the spray face.
IMPORTANT! The setscrews must be flush with the edge of the spray face
surface. If the setscrews protrude outside of the spray face frame, product
damage will occur.
Kohler Co.
Membrane
Align logo with
setscrew hole.
3
Groove
1083256-9-A