10. Service Schedule

Perform Service at Intervals Indicated (X)
Fuel System
Check the fuel level and fill as necessary
Check fuel lines and replace as necessary *[
Replace the fuel filter *[
Lubrication System
Check crankcase oil level and add as necessary
Replace the oil in crankcase *
Replace the lube oil filter element *
Cooling System
Check coolant level and fill as necessary *
Check seawater outlet and clean as necessary [
Check function of siphon break, if equipped
Check and clean seawater flow switch *
Replace seawater pump impeller *[
Adjust seawater pump tension *[
Check heat exchanger anticorrosion zinc
condition *
Replace heat exchanger anticorrosion zinc *
Flush cooling system *[
Ignition System
Check spark plugs condition and gap *
Replace spark plugs *
Intake/Exhaust System
Inspect exhaust system components *[
Check the exhaust gas condition
Service backfire flame arrestor *
Check and/or replace the catalyst assembly *[
Replace the CO sensor module *[
Check the crankcase breather pipe for obstructions *[
Inspect the complete exhaust system ***
Electrical System
Keep battery charged and in good condition 
Check and tighten electrical connections *
Clean battery cables [
Engine And Mounting
Check for water, fuel, coolant, and oil leakage *[]
Retighten all nuts and bolts *
Check tightness of mounting bolts/vibromounts *
Remote Control System
Check remote control operation
Generator
Test run generator set
Blow dust out of generator *[
Clean slip rings and inspect brushes *[
*
Requires removal of sound shield, if installed.
Consult your local distributor/dealer for service.
[
Read WARNING found at the beginning of manual regarding moving parts.
]
TT-1617
12/13
After
Before
50 Hr or
100 Hr or
Starting
1 Month
3 Months
X
X
X (200 hr)
X (200 hr)
X
X (during
operation)
X
X (during
operation)
X
X
X (200 hr)
X
X
X (200 hr)
X (break-in
period)
X (weekly)
*** Should be performed by your local distributor/dealer.
Consult battery manufacturer's instructions.
Every
Every
Every
300 Hr or
500 Hr or
6 Months
Yearly
X
X
X
X
(check)
X (200 hr)
X
X (1000 hr/
2 years)
X
X (250 hr)
X
X (every
2 years)
X
X (1000 hr.)
X
X
X
X
X
X
X
X
9