Kohler 1.1746.005 Installations- und Benutzerhandbuch - Seite 24

Blättern Sie online oder laden Sie pdf Installations- und Benutzerhandbuch für Armaturen für das Badezimmer Kohler 1.1746.005 herunter. Kohler 1.1746.005 29 Seiten.

Kohler 1.1746.005 Installations- und Benutzerhandbuch
Servicing
Warning! There are no user serviceable parts inside the shower. Servicing
of the shower must only be carried out by qualified, competent personnel
following the instructions provided in this guide and those provided with
any spare part. Before replacing any parts, ensure that the underlying cause
of the malfunction has been resolved.
Cleaning the Inlet Filter
Warning! Isolate the electrical and water
supplies before removing the cover.
1
Remove the shower hose.
Note: Retain the hose washer
for further use
2
Remove the three screws that
hold the cover on the shower and
remove the cover.
3
Remove the service tunnel from
the shower.
4
Use a suitable spanner to remove
the filter from the inlet connector
assembly. Hold a wrench across
the flats of the inlet connector
assembly to prevent damage to
the connector, whilst removing
the filter.
5
Remove the filter and rinse under
a running tap to remove any
lodged particles. If necessary, use
a kettle descalent in accordance
w i t h t h e m a n u f a c t u r e r ' s
instructions.
Refit the components in reverse
6
order.
1494247-W2-A
Screws
Cover
Hose
Washer
Inlet Connector
Assembly
24
Inlet Filter
Screw
Service
Tunnel