3. INSTALLATION

A. REMOVE WALL JAMBS
Slide wall jamb off each return panel.
Place return panels out of way of installation on a clean
and non-abrasive surface (such as a drop cloth) to
prevent damage.
B. WALL JAMB INSTALLATION
Place masking tape along the top of the receptor curb.
K-705230: Dimension A = 35-7/16" (90cm)
K-705231: Dimension A = 46-11/16" (118.6cm)
K-705232: Dimension A = 38-5/8" (98.1cm)
K-705233: Dimension A = 36-3/16" (91.9cm)
Measure from finished wall the specific dimension "A" and
mark a pencil line on the receptor ledge near the adjoining
wall.
Repeat measurement for other side.
Align the outside edge of each wall jamb with the marks
made on the receptor ledge. Using a level, plumb the wall
jambs and mark the four wall-mounting hole locations on
each wall with a pencil.
Kohler Co., Kohler, WI U.S.A.
Wall Jamb
Mark Hole Locations
(Four each side )
3
Return Panel
"A"
"A"
BC