Kohler BodySpa K-1000 Installationsanleitung Handbuch - Seite 25

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Armaturen für das Badezimmer Kohler BodySpa K-1000 herunter. Kohler BodySpa K-1000 28 Seiten. Tower custom hydro-massage system
Auch für Kohler BodySpa K-1000: Handbuch für Hausbesitzer (48 seiten)

Kohler BodySpa K-1000 Installationsanleitung Handbuch
B. TROUBLESHOOTING
Here's what you need to do if you require service: First review the installation instructions to ensure correct installation.
If you are unable to correct the problem, call our Customer Service Department for direct help. Dial 1-800-4-KOHLER.
SYMPTOMS
1. BodySpa does
A. No power to pump/control.
not start/stop.
B. Harness is blocked.
C. Keypad disconnected from pump/control
D. Faulty keypad.
E. Faulty circuit board.
F. Faulty motor/pump assembly.
G. Not enough water in footbath.
2. Water flow
A. Not enough water in footbath.
surges.
surges
B. Suction blocked.
C. Harness is blocked.
3. Motor starts, all
A. Jet is blocked.
Body Jets are
Body Jets are
B. Faulty keypad.
not functioning.
not functioning.
C. Butterfly valve wiring loose or damaged,
4. Motor starts,
A. Waterfall is blocked.
waterfall does
waterfall does
B. Faulty keypad.
not function.
not function.
C. Butterfly valve wiring loose/damaged –
5. Water increases
A. Variable flow valve wiring error.
when
keypad
button is
pressed –
decreases when
button is
pressed.
6. Waterfall light
A. Light bulb is burned out.
does not work
does not work.
B. Loose or damaged wiring.
7. BodySpa stops
A. GFCI trips.
automatically
automatically
B. Motor overheated and protection device
before 18
minutes.
8. BodySpa does
A. Faulty timer mechanism.
not
automatically
automatically
B. Wiring error.
stop after 22
minutes.
9. Noisy operation.
A. Pump strap has not been cut.
B. Not enough water in footbath.
Kohler Co., Kohler WI U.S.A.
PROBABLE CAUSES
box.
or butterfly valve is faulty.
butterfly valve is faulty.
activated.
A. Set/Reset GFCI breaker; check wiring to
pump/receptacle.
B. Remove blockage.
C. Reconnect keypad.
D. Replace keypad.
E. Replace circuit board inside control box.
F. Replace motor/pump assembly.
G. Fill footbath to drain overflow.
A. Fill footbath to drain overflow.
B. Remove obstruction.
C. Remove blockage.
A. Remove blockage.
B. Replace keypad.
C. Identify source of fault and correct, or
replace faulty butterfly valve.
A. Remove blockage.
B. Replace keypad.
C. Identify source of fault and correct, or
replace faulty butterfly valve.
A. Reverse variable flow valve wire
connections.
A. Replace light bulb.
B. Identify source of fault and correct.
A. Identify source of fault and correct.
B. Check for blockage at motor vents.
Remove blockage and allow motor to
cool.
Check for suction/harness blockage.
Remove blockage and allow motor to
cool.
A. Replace timer board inside pump/motor.
B. Refer to dealer.
A. Cut strap with tin snips.
B. Fill footbath to drain overflow.
25
CORRECTIVE ACTION
116290-2-
AB