Kohler K-10586 Installationshandbuch - Seite 8

Blättern Sie online oder laden Sie pdf Installationshandbuch für Armaturen für das Badezimmer Kohler K-10586 herunter. Kohler K-10586 48 Seiten. Bidet faucet
Auch für Kohler K-10586: Handbuch für Hausbesitzer (32 seiten), Handbuch für Installation und Pflege (24 seiten)

Kohler K-10586 Installationshandbuch
Fixture
6. Drain Installation-Style B
Remove the protective cover from the flange.
Apply a ring of plumbers putty or other sealant to the underside
of the flange according to the putty manufacturer's instructions.
Assemble the nut, flat washer, and tapered gasket (tapered side
up) fully onto the body.
From the underside of the fixture, insert the drain body up into
the drain hole.
From the top of the fixture, securely hand tighten the flange onto
the drain body.
Make sure the drain body seal hole is facing the back of the
fixture, and securely tighten the nut.
Remove any excess putty or sealant.
1010448-2-F
Flange
Apply plumbers putty.
Gasket
Washer
Nut
Drain Body
8
Kohler Co.