Original Issue Date: 4/15
Model: 13EKOZD/11EFKOZD, 15EKOZD/13EFKOZD, 16.5/17.5/19.5/20EFKOZD,
Market: Marine
Subject: Sound Shield Kits with Front Connection Panel GM93548-KP1,
Introduction
The sound shield quiets operation of generator sets
used in marine applications. When installing the sound
shield, follow the installation procedure and observe the
safety precautions listed below. See Figure 1 for kit
selection.
Take into consideration the minimum clearance for
vibration and cooling during operation. For sound
shielded units, allow 305 mm (12 inches) minimum
clearance for the service and non-service side doors
(intake and discharge openings).
Model
13EKOZD/11EFKOZD
15EKOZD/13EFKOZD
17.5/16.5EFKOZD
20EKOZD
20/19.5EFKOZD
23EKOZD
Figure 1 Sound Shield Kit Selection
INSTALLATION INSTRUCTIONS
20EKOZD/17.5-16.5EFKOZD, and 23EKOZD/20-19.5EFKOZD
GM93548-KP2, GM93548-KP3, GM93548-KP4, GM95106-KP1, and
GM95106-KP2
Kit Number
GM93548-KP1
GM93548-KP4
GM93548-KP2
GM95106-KP1
GM93548-KP3
GM95106-KP2
Safety Precautions
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Press the generator set off/reset
button to shut down the generator set. (2) Disconnect the
power to the battery charger, if equipped. (3) Remove the
battery cables, negative (--) lead first. Reconnect the negative
(--) lead last when reconnecting the battery. Follow these
precautions to prevent the starting of the generator set by the
remote start/stop switch.
WARNING
Risk of fire.
Can cause severe injury or death.
Do not smoke or permit flames or
sparks near fuels or the fuel system.
Servicing the fuel system. A flash fire can cause severe
injury or death. Do not smoke or permit flames or sparks near
the fuel injection system, fuel line, fuel filter, fuel pump, or other
potential sources of spilled fuels or fuel vapors. Catch fuels in
an approved container when removing the fuel line or fuel
system.
TT-1651 4/17a
the
generator
set.
Accidental starting can
Before working on the