Aqua Cooler AC-MWSM8EBFY-ASM Gebrauchs- und Pflegeanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Gebrauchs- und Pflegeanleitung für Kühler Aqua Cooler AC-MWSM8EBFY-ASM herunter. Aqua Cooler AC-MWSM8EBFY-ASM 7 Seiten. Semi-recessed bottle filler

INSTALLATION CONT.
CONNECTING THE CHILLER
A - Attach cradle to frame per rough-in drawing
B - Place chiller in frame
C - Install 1/4" union fittings on chiller inlet and outlet
D - Run the water line from the bottle filler solenoid valve "out" to chiller "in". Cut off excess
and use it to run from chiller "out" to the bottle filler delivery tube.

FILTER LOCATION

A - Screw filter clip to unit in location as shown.
(screw provided)
B - Install 1/4" stem elbows (provided) in filter
inlet and outlet
C - Place filter in clip as shown below.

FILTER INSTALLATION

A - Mount filter clip to frame
B - Install provided stem elbows
C - Cut water line from solenoid valve to bottle
filler delivery tube.
D - Connect solenoid valve out to filter in
E - Connect filter out to filler delivery tube
Your Partner in Cool.
6
INSTALLATION CONT.
TRIM BEZEL INSTALLATION
A - Install frame assembly to a flat surfact. Use appropriate fastening hardware (not included).
Refer to front of instruction manual for correct installation height.
B - Remove bottom plate from trim bezel (4 screws)
C - Install trim bezel to frame assembly and replace bottle plate with screws
D - Install drain assembly, snap bushings and any other accessories included with this kit.
E - Install upper and lower front panel.
7