Aqua Cooler AC-MW8EBFY-ASM Gebrauchs- und Pflegeanleitung - Seite 3

Blättern Sie online oder laden Sie pdf Gebrauchs- und Pflegeanleitung für Water System Aqua Cooler AC-MW8EBFY-ASM herunter. Aqua Cooler AC-MW8EBFY-ASM 8 Seiten. Wall-recessed bottle filler

IMPORTANT INFORMATION ABOUT GROUNDING
To provide additional protection from the risk of shock, this unit must always be connected to
a residual-current device (RCD) or a breaker. Use of joint cable should be avoid.
This appliance must be grounded. Improper use of the grounding plug can result in a risk of
electric shock, causing serious injury and possibly death.
This appliance is equipped with the power terminal or power cord. A ground connection
must be connected into a properly grounded, polarised outlet.
Consult a qualified electrician if the grounding instructions are not completely understood, or
if doubt exists as to whether the appliance is properly grounded.
Do not under any circumstances cut or remove the third (ground) prong from the power cord
plug (if provided). Do not use an adapter plug with this appliance.
INSPECTION
Inspect the cartons and various components for evidence of rough handling and concealed
damage. Damage claims should be filed with the carrier.

INSTALLATION

The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2, as well as the
instructions below. Pipe jointing and installation is a trade skill and Aqua Cooler recommended
this process is performed by qualified personnel only.
This drinking water cooler is designed to be operated at a water supply line pressure of up to
690kPa. The maximum operating temperature is 40°C. A pressure regulator must be installed in
front of the unit's water inlet. (see End Connection section)
OVERLOAD PROTECTION (systems with chiller)
The compressor motor is equipped with an automatic reset protector which will disconnect the
motor from the line in case of overload.
LUBRICATION (systems with chiller)
This unit is equipped with a hermetically sealed compressor. No additional lubrication is required.
The fan motor installed on this unit seldom needs oiling. If required, a few drops of SAE 10 oil
should be used.
Your Partner in Cool.
4
INSTALLATION
STEP 1 - INSTALL FRAME ASSEMBLY
Install frame assembly per rough in drawing. Note, the front flange of the frame must be flush
with the finished wall surface unless a trim bezel is desired.
Secure cradle mounting angles to the frame flange using the screws provided. Do not tighten
the screws. Slide cradle between the angles and attach to the angles with screws provided.
Tighten all screws.
Place chiller in frame cradle
Install drain assembly
Install snap bushings
5