Aqua Creek Products F-RNGR2-04 Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Hebesysteme Aqua Creek Products F-RNGR2-04 herunter. Aqua Creek Products F-RNGR2-04 16 Seiten. Pool lift

Anchor Installation: Core-Drill Retro-Fit

NOTE: FOR DECKS 6" THICK OR MORE, 2500PSI MINIMUM STRENGTH CONCRETE REQUIRED
You will need:
• Core drill and 1½" core drill bit
• Tape measure
• Marking pen
• Hammer
• Cold chisel
• Torpedo level
• High strength 2-part construction epoxy*
• Masking tape
• Black electrical tape (optional)
• Anti-seize packet
*Aqua Creek recommends either Hilti™ Brand HIT RE-500-
SD or Simpson™ brand SET-XP or equivalent
FIGURE 2
NOTE: Local bonding regulations may require you to drill one hole larger than the others in order to bond at least
one of the anchor inserts. You may need to saw cut a portion of your deck.
See "Saw Cutting Retro-Fit Instructions" on page 7.
Remove the nuts and the black protective coverings from the threaded anchor inserts.
3.
Copyright © 2020 Aqua Creek Products All Rights Reserved
(not included)
Anchor jig plate with hardware
Mark the 4 hole locations on your deck using
1.
the larger holes of the anchor jig plate as a
template. For ADA compliance, confirm the center
of the jig plate front holes are 14.5 to 19 inches
from the pool's edge.
Drill the 4 hole locations to 4 1/2 inches deep
2.
using the 1 1/2 inch drill bit. Clear all debris and
ensure holes are completely dry.
NOTE: Create a depth marker on the drill bit with black
electrical tape to make sure you drill to the right depth.
SEE FIGURE 2
Revised 1/10/20
5