AB Quality 2727-G7P20D1Q6 Schnellstart-Handbuch - Seite 18
Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Touch-Terminals AB Quality 2727-G7P20D1Q6 herunter. AB Quality 2727-G7P20D1Q6 20 Seiten.
18
MobileView Guard G750
MobileView Junction Box Cable
The MobileView Junction Box Cable (2727-MREX1) connects the Junction Box to
the circular jack in the wall of the enclosure. The cable length is 2 meters (6.5 feet).
When the MobileView terminal is not connected to the Junction box, the dust cover
provides protection for the 17-pin connector.
K1, 17-pin
MobileView
Circular Jack
Junction Box
Pin #
1
2
3
4
5
6
7
8
12
17
9
10
11
13
14
15
16
K3, 12-pin
connector for
terminal block X1
at Junction Box
K2, 8-pin RJ-45
jack (Ethernet) for
S1 at Junction Box
Publication 2727-QS002E-MU-P
Wire Color
pink
-->>
black
-->>
green-brown
-->>
white-green
-->>
grey-pink
-->>
red-blue
-->>
brown
-->>
yellow
-->>
green
-->>
grey
-->>
-
-->>
-
-->>
violet
-->>
blue
-->>
white
-->>
orange
-->>
red
-->>
K2,
K3, 12-Pin
8-Pin
Terminal
RJ-45
Block
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
-
-
12
-
11
1
-
2
-
3
-
6
-
K1, 17-pin circular jack
view from connector side
2 meter (6.5 ft)
Signal
Description
24V DC
GND_IN
E-stop, circuit 1, positive
E-stop, circuit 1, negative
E-stop, circuit 2, positive
E-stop, circuit 2, negative
Enabling switch, circuit 1, positive
Enabling switch, circuit 1, negative
Enabling switch, circuit 2, positive
Enabling switch, circuit 2, negative
Not Used
Not Used
Not Used
TD+ (transmit)
TD- (transmit)
RD+ (receive)
RD- (receive)
1
11
2
12
10
13
16
3
9
17
15
14
4
8
7
5
6
K1, 17-pin circular jack
mounts to enclosure
Dust Cover