Aqua Lung AIRSOURCE 3 Benutzerhandbuch - Seite 5
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Tauchinstrument Aqua Lung AIRSOURCE 3 herunter. Aqua Lung AIRSOURCE 3 7 Seiten.
AIRSOURCE III SECOND STAGE OWNERS MANUAL
CARE AND MAINTENANCE
The Airsource is constructed from carefully selected materials, which are
chosen to resist corrosion. However, the corrosive effects of the environment
in which diving equipment is often used cannot be entirely eliminated. Fur-
ther, the presence of sand and other minerals can interfere with the normal
operation of the equipment, and repeated prolonged exposure to chlorine
can accelerate deterioration of some components. Therefore, your equip-
ment will perform better and last longer if it is rinsed with fresh water after
each day's use.
The Airsource corrugated hose can be separated into two parts, which meet
in the middle and are connected by the Trim Grip™. The lower half (including
the MP hose) can be cleaned and stored with the first stage of your regula-
tor. The upper half can be cleaned, and remain on the BC until its next use.
Detach the medium pressure (MP) inflator hose from the hose guides at the
top and middle attachment points. While holding the molded hose steady
just below the Trim Grip™, grasp and turn the Trim Grip™ 1/4 turn clock-
wise, and pull down on the molded hose to disengage the lower assembly.
After proper cleaning, hold the lower molded hose and Trim Grip™ steady.
Engage the Airsource lower assembly by lining up the upper and lower con-
nection points and carefully turning counter-clockwise 1/4 turn. Slide the medium
pressure (MP) hose into the middle and upper hose guides.
NOTE:
When inserting the lower half of the Trim Grip™ into the up-
per half, make sure to rotate counterclockwise to prevent parts from
being damaged. When inserted correctly, the lower half of the Trim
Grip™ will only rotate in a counterclockwise direction. Avoid using
excessive force when connecting the two parts.
The recommended procedure for cleaning your Airsource is as follows:
1. Ideally, you should soak the entire Airsource in warm tap water (less than
120
F/40
C) to loosen mineral deposits. A large plastic trash can filled with
°
°
fresh water is useful for rinsing all of your diving equipment.
2. If warm water soaking is unavailable, rinse the Airsource in tap water. If no
air pressure is supplied to the Airsource, DO NOT DEPRESS THE PURGE
BUTTON! Pressing the purge button can cause water and mineral deposits
to reenter the unit, which can accelerate deterioration over time.
3. Remove any remaining excess water from the Airsource by thoroughly
wiping it dry with a soft towel. After it is dry, reconnect it to a scuba cylinder
and depress the purge button and the power inflator button to rid the unit
of excess water. Do not store the Airsource with air pressure supplied to it.
4. Store the Airsource in a clean equipment box or sealed plastic bag in a
cool, dry, dark place.
NOTE:
Do not use any cleaning solvents for soaking or rinsing.
Do not attempt to lubricate or preserve any part of the regulator
with aerosol cleaners or silicone spray. This is not necessary,
and the propellant and other chemicals in these compounds can
seriously damage the Airsource.
SCHEDULED SERVICE
The Airsource should be inspected/serviced by a qualified repair techni-
cian. Inspections should occur annually or more frequently (every three
to six months) if used heavily, in dirty water, swimming pools, or it is not
operating correctly. Heavy use is considered to be more than 100 opera-
tional hours within one year.
If the regulator is in good working order, it is permissible to overhaul it every
other year with an inspection procedure being performed on the "off" years.
For example:
Year #1 : Inspection
Year #2 : Overhaul
Year #3 : Inspection
Year #4 : Overhaul, and so on.
Both Inspections and Overhauls need to be documented in the Annual
Service & Inspection Record to keep the Limited Lifetime Warranty in effect.
As described in the warranty statement, your annual regulator inspection
and service must be performed by a qualified Aqualung
ensure best service at all times, please fill out the following service registra-
tion log, and have your dealer sign and date it in the appropriate spaces
each time the regulator is taken for inspection or repair. Be sure to maintain
records as proof of performance of maintenance.
WARRANTY INFORMATION
All warranty transactions must be accompanied by proof of original purchase
from an authorized dealer. Be sure to save your sales receipt, and present it
whenever returning your regulator for warranty service.
Limited Lifetime Warranty
Aqualung warrants to the original purchaser that the product will remain
free from defects in material and workmanship throughout its useful life; pro-
vided that it receives normal use, proper care, and prescribed dealer service
subject to those restrictions stated below.
This warranty does not apply to units subjected to misuse, abuse, neglect,
modification, or unauthorized service. This limited warranty is extended
only to the original purchaser for products purchased directly from an au-
thorized dealer, and is not transferable.
This warranty is limited to repair or replacement only at the discretion of
Aqualung America.
WARNING:
It is dangerous for untrained and uncertified persons
to use the equipment covered by this warranty. Therefore, use of
this equipment by an untrained person renders any and all war-
ranties null and void. Use of scuba equipment by anyone who
is not a trained or certified diver, or receiving training under the
supervision of an instructor, could lead to serious injury or death.
5
repair facility. To
®