Aqua Medic DC Runner 9.2 Betriebshandbuch - Seite 3

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Water Pump Aqua Medic DC Runner 9.2 herunter. Aqua Medic DC Runner 9.2 4 Seiten.

Aqua Medic DC Runner 9.2 Betriebshandbuch
There is an automatic shut off if there is no water for 2 minutes. Pull the plug and then re-insert it
to take the controller back into operation. Controller, plugs and sockets have to be kept dry.
0 - 10 V: The pumps must be operated with at least 60% power, otherwise damage will occur. Short
pulse rates are not possible due to the start-up delay on the pumps.
Press the FEED button until 4 LEDs (Fig. 4, No. 2) light up in the middle to activate the 0 - 10 V
socket. In the same way, the 0 - 10 V output can be deactivated again.
Fig. 4: DC Runner Controller
1. Feed button
3. Power supply
2. LEDs
4. 0 - 10 V socket
By keeping the minus and FEED buttons pressed and hold until the LEDs flash once, the keyboard
of the controller can be locked or unlocked.
5. Maintenance / Cleaning
From time to time, the pump needs to be cleaned. For cleaning, do the following:
First of all, remove
the bottom plate. Then, turn the basket and take it off the pump. Now, the complete impeller can be
taken out.
It can be cleaned under running water and then be
re-assembled. When assembling, make
sure that the ceramic shaft of the impeller goes into the socket of the respective bearing.
6. Failures
The pump is designed to have a low maintenance requirement and under normal conditions will be
very reliable, provided it is protected from contamination. If the pump gets noisy, the suction basket
and the propeller need to be cleaned or the impeller and bearings need to be replaced.
7. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. Proof
of Purchase is required by presentation of the original invoice or receipt indicating the dealer's name,
the model number and date of purchase. This warranty may not apply if any model or production
number has been altered, deleted or removed, unauthorised persons or organisations have executed
repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. Please note
that the product is not defective under the terms of this warranty where the product, or any of its
component parts, was not originally designed and / or manufactured for the market in which it is
used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 03/2018
Current manuals are available for download at www.aqua-medic.de.
8