Allied Systems Long Reach BHA Series Handbuch für Installation, Wartung und Service - Seite 19
Blättern Sie online oder laden Sie pdf Handbuch für Installation, Wartung und Service für Hebesysteme Allied Systems Long Reach BHA Series herunter. Allied Systems Long Reach BHA Series 20 Seiten. Billet handler
5.7 Wear Plug Replacement
1. Remove the two threaded plugs located underneath
the rack weldment. ( Figure 5-8)
Front of Attachment
Wear Plug
Plug Insert
Threaded Plug
Figure 5-8, Wear Plugs
2. Remove the old wear plugs.
3. Replace the plug inserts located in the threaded plugs
before reinstalling.
4. Install the new wear plugs and secure them in place
with the threaded plugs.
5.8 Gripper Pin Replacement
1. Check gripper pins for wear or cracks. Replace them
when necessary.
2. Loosen the capscrew that secures the gripper pin. It
may be necessary to heat the bolt head to soften the
loctite that secures it. While holding the gripper pin
remove the capscrew that holds the gripper pin in
place. (Figure 5-9)
45-053, REV. 5/18
Capscrew
Washer
Slotted Washer
Gripper Pin
Figure 5-9, Wear Plugs
3. Insert the new gripper pin and secure it with the cap-
screw that has been treated with Loctite threadlocker
272 (red). Torque the capscrew to approximately 1000
ft-lbs.
5.9 Grease Fitting Locations
1. Use a standard lithium grease when necessary on the
grease fittings located in the gear pins. (Figure 5-10)
Grease Fitting
Locations
Figure 5-10, Grease Fitting Locations
19