Installing
underbench module.
1. Flush Water Supply
Flush water supply pipework before installing
the underbench unit by connecting 600mm
flexible braided hose to the supply tap and
running water into a bucket.
2. Install Underbench Unit
Take care to observe minimum clearances.
This is particularly important with air-cooled
models. Ensure there is adequate access to
service the unit.
3. Connect Dispenser Tubing
and Electrical Plug
Connect all tubing and electrical plug as
shown in Diagram 8 & 9.
Ensure correct orientation of dispenser
power plug before insertion. Trim tubes
to correct lengths using a sharp knife or
plastic tube cutter. Avoid leaving excess
tubing which will sag, trapping water.
Fit spring clamps supplied to retain
silicone rubber tubing to barbed fittings
IMPORTANT: Boiling outlet (red) and vent
tube (grey) must not be kinked and must
be installed with a continual fall.
4. Commission the System
a. Turn blue temperature control
knob to OFF.
b. Turn electricity supply ON at wall outlet.
c. Turn water supply tap ON.
d. Check that there are no leaks.
e. Wait for unit to calibrate (10-15mins).
The red and blue lights will come on then
red only . Wait till unit has steamed and
red and blue lights come back on.
Determine which tap your unit has
– refer to diagrams 2a, b & c.
5. Enter Pipe Length Calibration Mode
To enter SETUP mode, turn on the unit
and wait for normal operation.
Now depress both the Hot and Cold levers
and while they are down, touch and rest
your finger on the safety switch (safety
switch is indent located on the back of
the tap) for 3 seconds until the display
has changed to yellow, then release the
switch and both levers.
Once in SETUP mode, repeat the procedure
for entering setup – this will take you to the
pipe length calibration mode. The red and
blue tap indicators will now blink: blue
slowly and red faster.
To change the pipe length:
a. Press and release the Hot Lever
to reduce the pipe length.
b. Press and release the Cold Lever
to increase the pipe length.
c. After each press wait for the tap to
demonstrate the dispense operation.
No water should be dispensed when
the correct length is selected.
d. The best way to determine the correct
pipe length setting is to increase the
length (by pressing the Cold Lever
or touching the cold (blue) icon) until
a splash of water is observed, then
decrease the length (by pressing the
Hot Lever or touching the hot (red) icon)
until no splash is observed.
Press or touch the safety switch to
save the new settings.
6. Flush the Unit
a. Latch cold (left) lever into the UP position
b. When cold water stops running,
return cold lever to OFF position
c. Wait for 10 minutes
d. Latch cold lever into the UP position
e. When cold water stops running,
return cold lever to OFF position
f.
Latch hot lever into the UP position
g. When hot water stops running,
return hot lever to OFF position
Re-check Connections for Leaks
Explain Operation to User
INSTALLATION AND
COMMISSIONING CHECKLIST
Filter packing foam removed from
under filter cannister.
Dispenser mounted securely.
Dispenser swivels 45º in each direction
– Locking piece is removed
Tubing is cut to correct lengths and
not kinked or sagging. Red, grey and
10mm black tubes have a continual fall.
Tubing not twisted or kinked.
Tubing secured correctly
– nuts and spring clips.
Water main flushed before connection
to unit.
Unit connected to COLD water supply.
Correct air clearances around unit.
Power circuit fitted with an RCD
– earth leakage protection device.
Sawdust cleaned out of cupboard area.
Initial program settings correctly set
for dispenser tube length.
Unit heating and cooling (after initial fill).
Red and blue dispenser icons flashing
(or on continually when reached
temperature).
Boiling and chilled water flow correct.
Billi (UK) LLP
Synergy House
Fakenham Road Morton
Norwich
NR9 5SP
London Showroom:
Synergy London
15 Dufferin Street
London
EC1Y 8PD
WARNINGS.
For continued safety of this appliance
it must be installed, operated and
maintained in accordance with the
manufacturer's instructions.
— Your appliance should be installed by
a suitably qualified tradesperson.
— For correct operation of this appliance
it is essential to observe the instructions
as outlined in this booklet.
— Do not use this appliance with water
that is microbiologically unsafe or with
water of unknown quality without adequate
disinfection before or after the system.
Systems certified for cyst reduction may
be used on disinfected water that may
contain filterable cysts.
— Filter replacement must be performed
at intervals of not more than 6 months.
— Use this appliance only as directed in these
instructions and only for its designed purpose.
— This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
— Children should be supervised to ensure
that they do not play with the appliance.
— DANGER: The operation of the thermal
cut-out indicates a possibly dangerous
situation. Do not reset the thermal cut-out
until the water heater has been serviced
by a qualified person.
— WARNING: Do not connect any restrictor
or pressure relief device to the vent pipe
of this water heater if installed.
— If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
— New hose-sets supplied with the appliance
are to be used and old hose-sets should
not be re-used.
+44(0)20 7456 6789
www.billi-uk.com
As Billi (UK) LLP has a policy of continual improvement, all details are
subject to change without notice. All goods are sold subject to our
published terms and conditions.
Billi is a registered trademark.
© 2017
power cord
flexible hose
1/2" stop tap
(installed by plumber)
Diagram 9