Abacus Electric Evolve Sonix Benutzerhandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Sicherheitssystem Abacus Electric Evolve Sonix herunter. Abacus Electric Evolve Sonix 10 Seiten. Wireless gsm alarm
Wireless PIR detector
- Power supply: DC9V (inner 9V battery)
- Static current: ≤100 mA
- Transmission current: ≤20 mA
- Transmission frequency: 315/433 ± 0,5 MHz
- Wireless coverage: in open space 80 m
- Detection speed: 0,3 – 3 m/s
- Detection distance: 5 ~ 12m
- Detection coverage: horizontally 110°, vertically 60°
Troubleshooting:
Signs
The alarm cannot be
activated by the phone
It is necessary to use the
remote control from near
and the warning light shines
too weakly
The warning of the door
sensor and PIR shines
permanently
Dialling is slow
The main drive doesn´t
receive the signals from the
sensors
Do not place the alarm near the devices that might emit strong electromagnetic interference (e. g. motors,
computers, and so on). Put the alarm main drive to the hidden place. The main drive must have all the cables
tightly connected and mustn´t be covered – because of the easy heat supply. Sonix is made for the inner use only
2200 DECLARATION OF CONFORMITY:
Hereby, the company ABACUS Electric s. r. o. declares that this model EVOLVE Sonix is in compliance with the
requirements of the norms and regulations, relevant for the given type of device. The complete text of
Declaration of conformity can be found at ftp://ftp.evolve-europe.com/ce/.
EVOLVE support: the files for downloading, settings, manuals and other information relating to the EVOLVE
products can be found at
Copyright © 2013 ABACUS Electric s. r. o.
All rights reserved. Design and specification can be changed without prior notice.
Reasons
1. The alarm wasn´t turned on
2. It hasn´t been on long enough
– at least 30 seconds
3. The wrong number was set
4. Counterparts of the
window/door sensors were
installed too far from each
other
5. The PIR sensor wasn´t
activated
6. The code wasn´t checked
1. The battery in the remote
control is rusted
2. The battery is low
The battery is low
The main drive has saved
different numbers
The code wasn´t checked
www.evolve-europe.com
- Operation conditions: temperature –10°C ~ + 40°C
/ humidity ≤ 90% rh
Remote control
- Power supply: DC12V (inner 12V battery)
- Transmission current: ≤15mA
- Transmission frequency: 315/433 ± 0,5 MHz
- Wirelesscoverage: in open space 80 m
Solving
1. Turn on the alarm
2. Activate it 30 seconds after turning on
3. Set the number again and exactly according
to the instructions
4. Set placing of the sensors' counterparts
5. Activate PIR
6. Check the code
1. Remove the rust
2. Change the battery
Change the battery
Set the numbers again and exactly according
to the instructions
Check the code
51