INSPECTION
1. Check if the pump is connected to a compatible source of electric power.
2. Make sure the pump has contact with liquid, which is going to be transferred
(running the pump in a constant dry state is strictly forbidden).
3. Make sure the ground wires are connected and the switch is turned OFF.
4. If transferring a certain liquid may easily lead to static electricity occurrence, by all
means use a ground wire not only with the motor, but also with liquid's container.
USAGE
1.
Open the valve ③, insert device's suction pipe into the liquid.
2.
Make sure the switch is turned off. Connect the device to the power source.
3.
Close the valve ③ and turn the switch ON. Then open the valve ③ gradually, to
adjust the delivery rate.
4. After use、turn the switch OFF and unplug the device from the power source.
[Valve ③ location is marked on the next page.]
TECHNICAL SPECIFICATIONS
Model
Max delivery rate
Max uplift (clear water)
Max temperature
Operated by
KFC103-N
80L/min
16m
60℃
ELECTRIC MOTOR
Power source AC100V 4A (single phase)
Frequency
50/60Hz continuous rating
Power
160W
Cord
PVC, 4.7m
KFC104-N
14m