Troubleshooting

Symptoms
The pilot flame cannot be lit.
The pilot flame is on but the main
burner cannot be lit.
There is a light-back sound when
turning off the gas supply.
Unit has red flame and black smoke.
The issues mentioned above are for reference. If any failure occurs, please stop using and contact
Cooking Performance Group. Safety is first and maintenance should be done after shutting down the
power supply and gas supply.
Cooking Performance Group
Causes
1. Plug or plug cord of igniter is
damaged.
2. Pressure in the gas pipeline is too low.
3. The pilot nozzle is blocked.
4. Thermocouple connection is loose.
5. The thermocouple is defective.
6. The gas control valve is defective.
1. Pressure in the gas pipeline is too low.
2. Main nozzle is blocked.
3. The gas control valve is defective.
4. Gas regulator not set up properly
1. Nozzle diameter does not match with
the gas supply.
2. The supply pressure is too low.
3. Flow within the connected pipe is too
low.
1. Nozzle diameter does not match with
the gas supply.
2. Low gas supply.
3. Gas ingredients are volatile in gas
peak period.
13
1. Replace relevant fittings.
2. Regulate the reducing valve or contact
the gas supplier.
3. Unblock the nozzle.
4. Tighten the thermocouple.
5. Replace the thermocouple.
6. Repair or replace the gas control valve.
1. Regulate the reducing valve or contact
the gas supplier.
2. Unblock the nozzle.
3. Repair or replace the gas control valve.
4. Verify regulator is installed correctly,
verify arrow on regulator points
towards to unit. Make sure the dual
gas regulator was setup to the correct
gas being supplied to the unit
1. Regulate the nozzle diameter.
2. Regulate the reducing valve or contact
the gas supplier.
3. Increase the permitted flow.
1. Regulate the nozzle diameter.
2. Increase the gas supply.
3. Decrease the gas flow. Increase it after
the peak.
https://www.cookingperformancegroup.com/
.
Solutions