Avtron AV115 Anleitung Handbuch - Seite 9
Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Medienkonverter Avtron AV115 herunter. Avtron AV115 10 Seiten.
THIN-LINE II™
Application Examples
Applies to all model AV115 encoders, except for wiring option "G".
Avtron THIN-LINE II encoders provide an alarm signal if maintenance is required under specific circumstances. An optional internal
alarm LED indicator is also available. Green indicates power on, red indicates alarm on. Following are application examples
provided to help install the alarm output.
Example 1. Alarm output using +V(OUT). +V(OUT) is equal to +V, the encoder power supply.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
Q5
MMFT6661
Example 2. Alarm Output Using Separate 24 VDC Power Supply and Relay.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
ALARM OUTPUT CONNECTION
OUTPUT OPTIONS
"W"
"P" & "Q"
{
BLACK
RED
CR8
GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE
BROWN
VIOLET
OUTPUT OPTIONS
"W"
{
BLACK
RED
CR8
GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE
BROWN
VIOLET
Q5
MMFT6661
FUNCTION
1
COMMON
6
+V (Encoder Power)
2
ØA
7
ØA
3
ØB
8
ØB
4
MARKER
9
MARKER COMPLEMENT
5
10
GND
4-16 VDC SOLID STATE RELAY
"P" & "Q"
1
6
2
ØA
7
ØA
3
ØB
8
ØB
4
MARKER
9
MARKER COMPLEMENT
5
10
GND
50 mA MAXIMUM
300 OHM
MIN.
Vcc
OUT
COM
FUNCTION
COMMON
+V (Encoder Power)
-
24
POWER
SUPPLY
VDC
+
RELAY
SINK 100 mA MAXIMUM,
WITHSTAND 50 V MAXIMUM
REFERENCED TO COMMON
115 VAC
9