M
icroprocessor and Terminator Module
memory module
secondary
microprocessor or
terminator module
primary
microprocessor
module
Figure 4. Microprocessor and Terminator Module Removal
1. Remove the left computer cover.
2. Remove the support panel.
3. Remove the microprocessor or terminator module.
Grasp the module by the corners and carefully pull the module out until the
edge connectors are free from the system board connectors.
NOTES: Both microprocessor module connectors must be populated. The
secondary connector must have either another microprocessor module or a
terminator module.
Be careful not to touch components or the gold edge connectors on the
module.
Dell PowerEdge 6100/200 System Microprocessor Replacement