Dell D560F Benutzerhandbuch - Seite 12

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Server Dell D560F herunter. Dell D560F 33 Seiten. Emc vxrail appliances on poweredge servers

Dell D560F Benutzerhandbuch
Figure 4. Status LED indicators
Table 10. Status LED indicators and descriptions
Icon
Description
Drive indicator The indicator turns solid
Temperature
indicator
Electrical
indicator
Memory
indicator
PCIe indicator The indicator turns solid

System health and system ID indicator codes

Figure 5. System health and system ID indicators
Table 11. System health and system ID indicator codes
System health and system ID indicator code
Solid blue
12
Dell EMC VxRail D Series overview
Condition
amber if there is a drive error.
The indicator turns solid
amber if the system
experiences a thermal error
(for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid
amber if the system
experiences an electrical error
(for example, voltage out
of range, or a failed power
supply unit (PSU) or voltage
regulator).
The indicator turns solid
amber if a memory error
occurs.
amber if a PCIe card
experiences an error.
Corrective action
Check the System Event Log to determine if the drive has an
error.
If the problem persists, see the
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● Appliance cover, air shroud, memory module blank, or back
filler bracket is removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or appliance messages for the
specific issue. If it is due to a problem with the PSU, check the
LED on the PSU. Reseat the PSU.
If the problem persists, see the
See the
Support
section.
See the
Support
section.
Condition
Indicates that the system is turned on, system is healthy, and
system ID mode is not active. Press the system health and
system ID button to switch to system ID mode.
Support
section.
Support
section.
Support
section.