Removing a Processor
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Press down on the heat-sink release lever and rotate the clip away from the processor
1
socket. See Figure 1-7.
Remove the heat sink and clip. See Figure 1-7.
2
F i g u r e 1 - 7 .
NOTICE: Be careful not to use excessive force when opening the processor socket. Excessive
force could damage the socket.
Using a flat-tip screwdriver, insert the screwdriver into the opening slide slot (toward
3
the back of the server module) and gently pry the processor socket to the fully open
position. See Figure 1-8.
1-10
Repl aci ng the S er v er Mo dule Bo ard
R e m o v i n g a n d I n s t a l l i n g t h e H e a t S i n k
release lever
heat-sink clip
heat sink