How It Works
The AquaSolvo Eco Air Sterilizer has a two
stage cleaning system to disinfect the air. A
fan draws air in through the pre-filter at the
bottom of the sterilizer. Inside, the air passes
through the CEF and exits through the top
cover. The two stages to the sterilizer are:
• Stage 1: Pre-Filter . The pre-filter has
a screen that captures large airborne
particles.
• Stage 2: CEF. The CEF absorbs the HOCl
water generated in the water tank. The
HOCl water is evaporated as air passes
through the CEF. This disperses the HOCl
molecules throughout the airspace in the
room allowing it to destroy a variety of
bacteria and viruses.
Product Specifications
Model Number
AAE-30XX06 (XX is the product color code)
Power Consumption
21 Watts
Input Voltage
120 VAC 60Hz
Fan Speed
3 levels (Sleep/ 2/ 3)
Noise (dB(A))
Max. 52
Water Tank Capacity
1800ml/60.87oz.
HOCl Recipe
2 scoops non-iodized salt: 1800ml/60.87oz. tap water
Material & Finish
ABS, Glossy White & Silver belt
Recommended Room Size
320 square feet
- Filter Replacement Reminder: Cold evaporation filter
Reminder
- Salt Level Reminder
- Water Level Reminder
Dimensions
H11.8"xDia8.7"(H300x Dia222mm)
Net Weight (without water)
5.29 lbs (2.4 kg)
5
Unpacking and Setup
1. Remove the Sterilizer from the box and
check that all the items shown in Figure 1
are included. It is a good idea to retain the
packaging for storing the Sterilizer or in the
event it must be shipped back for service.
2. Remove the top cover and make sure the
CEF and CEF lid are securely in place.
3. Place the Sterilizer on a flat, solid surface in
proximity to an AC electrical outlet.
4. Connect the power cord to the Sterilizer,
and route the power cord to the outlet, but
do not plug it in yet. Make sure that the
power cord is out of the way and does not
pose a tripping hazard, and is out of reach
of children and pets.
Congratulations! You are now ready to enjoy
clean safe air using the AquaSolvo Eco Air
Sterilizer.
Control Panel
Figure 2. Control Panel
ON/OFF
HOCI disinfection works when it is on
Fan Speed
(Sleep/2/3) Three levels of fan speed
Sterilize
The light remains on when the machine is on and flash when
electrolysis is working to process HOCl.
CEF Replacement Indicator
Will remind you to change the CEF
6