VLAN ID
Use the LAN configuration command parameter 14H to set or get the VLAN ID. For additional
information, refer to the IPMI v2.0 specifications.
Table 1-36.
VLAN Commands
Commands
Set LAN Configuration
Parameters (Parameter 9 and 25 are not supported)
Get LAN Configuration
Parameters (Parameter 9 and 25 are not supported)
Table 1-37.
LAN Configuration Parameter 14H
Parameter
802. 1q VLAN ID (12-bit)
Examples:
Set VLAN ID:
•
Get LAN configuration parameter:
ipmitool 0xC0 0x02 0x01 0x14 0x00 0x00
Response: 0x00 0x11 0x01 0x80 (VLAN Enable and VLAN ID: 1)
•
Set LAN configuration parameter:
ipmitool 0xC0 0x01 0x01 0x14 0x01 0x80
Response: 0x00
NetFn
Transport
Transport
#
Parameter Data
14H
Data 1
[7:0] — Least significant 8-bits of the VLAN ID. 00h if
VLAN ID not used.
Data 2
[7] — VLAN ID enable.
0b — Disabled
1b — Enabled
If enabled, the BMC will only accept packets for this
channel if they have 802.1q fields and their VLAN ID
matches the VLAN ID value given in this parameter.
[6:4] — Reserved
[3:0] — Most significant 4-bits of the VLAN ID
CMD
O/M
01h