PS6000 Hardware Maintenance
Interpreting Control Module LEDs
Control modules have the following LEDs:
•
On the left side of each control module, three LEDs enable you to determine
the control module status and whether the control module is active or
secondary. See Figure 3-1.
•
Each Ethernet port has two LEDs that show the network interface status. See
Figure 3-1.
Control module LEDs are described in Table 3-1. Ethernet port LEDs are
described in Table 3-2.
Table 3-1: Control Module LED Descriptions
LED Location
ACT LED
ERR LED
PWR LED
3–2
Color
Description
Off
No power, secondary control module is not
synchronized with active control module,
or error condition.
Green
Active control module (serving network I/
O).
Orange
Secondary control module. Cache is
synchronized with active control module.
Off
Normal operation or no power.
Red
Array is starting up or error condition.
Off
No power.
Green
Power.