FOR YOUR SAFETY, READ BEFORE LIGHTING
Warning: If you do not follow these instructions exactly, a fi re or explosion may result, causing
property damage, personal injury, or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional
service technician to inspect the appliance and to replace any part of the control system and any gas
control that has been underwater.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the fl oor, as some
gas is heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS
ON PG. 1.
LIGHTING
1. Turn off any electrical appliance.
2. When operating remotely; fl ip the remote receiver control
to the REMOTE position, and turn the unit ON by using
the remote transmitter.
3. Alternately; fl ip the receiver switch to the ON position when
manually operated. This transmits a rapid series of sparks
at the pilot head and will ignite the gas.
Sparks cease when the pilot fl ame is lit and stable. after a short
time, the pilot will then light the main burner.
CAUTION: IF THE BURNER DOES NOT IGNITE WITHIN
20 SECONDS, STOP WAIT 5 MINUTES, THEN
REPEAT STEPS 1. THRU 3. ABOVE.
Normally, the pilot should remain lit. If it goes out, repeat step
2 or 3.
If the pilot will not stay lit after several tries, turn the receiver
to OFF and contact a qualifi ed professional service technician
or gas supplier.
In addition to these instructions; reference the separate remote
instructions for further details on the remote system.
If optional wall switch was purchased separately; refer to the
instructions supplied with the wall switch for lighting/operation.
PILOT APPEARANCE
Periodically check the pilot for proper fl ame pattern. The pilot
fl ame should encircle the generator tip, and is preset at the
factory (see Fig. 13-2).
If the pilot fl ame burns incorrectly; shut down completely
and contact a qualifi ed professional service technician.
SHUTTING DOWN
1. Simply fl ip the receiver switch to the OFF position when
manually operated. The gas fl ow will cease, and all the
fl ames (main burner and pilot) will go out.
2. For remote operation, press the OFF button on the
transmitter.

LIGHTING INSTRUCTIONS

13
ADJ.
LEARN
OFF
REMOTE
ON
Fig. 13-1 Receiver & Transmitter
Fig. 13-2 Proper pilot fl ame
ON
OFF