Dell PowerVault 715N Service-Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Service-Handbuch für Lagerung Dell PowerVault 715N herunter. Dell PowerVault 715N 44 Seiten. Network attached storage
Auch für Dell PowerVault 715N: Anweisungen aktualisieren (4 seiten), Benutzerhandbuch (31 seiten)

Dell PowerVault 715N Service-Handbuch
Memory module capacities
Minimum RAM
Drives
IDE hard drives

External Ports and Connectors

Serial
NIC
Power
Wattage
Input voltage
Output voltages
and maximum
current
Backup battery
Physical
Height
Width
Depth
Weight
Environmental
Temperature:
Operating
Storage
Relative humidity:
Operating
Storage
Maximum vibration:
128-, 256-, and 512-MB registered SDRAM DIMMs; must be rated for
133-MHz operation
256 MB for early systems with a SN1A system board, or 384 MB for later
systems with a SN1B system board
four 1-inch, internal hard drives with capacities of at least 40 GB
one 9-pin connector UART 16550-compatible
two RJ-45 connectors for connection to internal embedded NICs (Intel
82559 10/100 Ethernet controllers)
one 162-W power supply
100- to 240-V at 47–63 Hz, autoranging
+5 VDC at 15 A
+3.3 VDC at 8 A
+12 VDC at 8 A
–12 VDC at 0.1 A
+5 Vfp (volts flea power) at 1 A
CR2032 3-V lithium coin cell
4.2 cm (1.6 inches)
42.5 cm (16.7 inches)
46.3 cm (18.2 inches)
9.5 kg (21 lb) maximum configuration
10°C to 35°C (50°F to 95°F) at 10,000 feet above sea level
10°C to 40°C (50°F to 104°F) at sea level
–40°C to 65°C (–40°F to 149°F)
20% to 80%, noncondensing
5% to 95%, noncondensing