Dell PowerVault MD3620i Installationshandbuch - Seite 17
Blättern Sie online oder laden Sie pdf Installationshandbuch für Lagerung Dell PowerVault MD3620i herunter. Dell PowerVault MD3620i 18 Seiten. Dell powervault modular disk storage arrays
Auch für Dell PowerVault MD3620i: Support-Matrix (11 seiten)
Troubleshooting the SMI-S Provider
Table 4-1 lists some of the common issues and their resolutions.
Table 4-1. Common Issues and Resolutions
Issue
The following message is displayed if
SMI-S Provider is installed on a system
that previously did not have the SMI-S
Provider installed:
cimserver not started: Bind
failed: Failed to bind socket
on port 5989: Address already
in use (error code 125).
CIMOM default port in use is not
reported in the Microsoft Windows
operating system.
Service Location Protocol Service Agents
(SLP SA) in multi-CIMOM
environments.
Recommended Action
This issue occurs when there is a port
conflict. To resolve the conflict, remove
the application that is using the port or
select a different port.
To select a different port:
Stop the CIM server.
1
Set the new ports using the following
2
commands:
cimconfig -s httpPort=<HTTP
PORT> -p
cimconfig -s httpsPort=
<HTTPS PORT> -p
Start the CIM server.
3
In Windows, if the default ports 5988 and
5989 are already in use during the SMI-S
Provider installation, no message is
displayed to state that the ports are in use.
To resolve the conflict:
Edit the cimserver_current.conf and
1
cimserver_planned.conf files.
Specify the open ports.
2
Start the CIM server.
3
Only one SLP SA per individual server
can be active because SAs require the
fixed port 477.
NOTE:
If the operation started on a non-
standard port, dynamic SLP discovery of
the CIM service is not be possible.
Troubleshooting the SMI-S Provider
4
17