Auch für Dell PowerVault NX1950: Handbuch für den Einsatz (34 seiten), Wichtige Informationen Handbuch (26 seiten), Erste Schritte (49 seiten), Handbuch für den Einsatz (38 seiten), Upgrade-Handbuch (18 seiten), Referenzhandbuch (4 seiten), Einrichten (2 seiten), Verwendung von (2 seiten), Konfigurationshandbuch (11 seiten)

Dell PowerVault NX1950 Handbuch für Installation und Fehlersuche
Table 3-1. Adding a Node Manually
Step/Phase
Add the cluster to the Server Connections
1
Edit the Cluster Connection to include all nodes
2
Assign the Quorum Disk to the Cluster
3
Configure the RPC Locator Service as Automatic
4
and start the service
indicates that the step is applicable to the respective cluster component.
You must perform the actions in the table on each additional node for the
cluster to function properly. These steps assume that the Add Node wizard
has been run on the new node and the node is now ready to complete the
configuration setup.
Server Connections
After the cluster setup is complete, perform the following procedure to
update the server connections to reflect the cluster configuration.
1 Click Start
Server
Share and Storage Manager
LUN Management to start the PowerVault NX1950 management console.
2 In the LUN Management section, click Manage Server Connections.
3 The Manage Server Connections window appears. Click Manage Clusters
to add the cluster to the managed server connections.
4 In the Manage Clusters window, click Add.
5 Enter the name of the cluster and verify that the server is a local server.
Click OK.
The cluster appears in the list of managed server connections.
30
Managing Your Cluster
Administrative Tools
New Node(s) Existing Node(s)
Windows Unified Data Storage
Storage Manager for SANs