Table 1. Installation Issues
Issue
Error: -5004.
Error occurred
while
attempting to
create OS
volume.
Error: -5005.
Error occurred
while
attempting to
create OS
volume.
8
Troubleshooting Guide
(continued)
Description
Drives in the expected
system slots dedicated
for the operating system
are empty.
Drives in expected
operating system slots
have existing foreign
configurations.
Workaround / Solution
To workaround this issue, perform
one of the following steps:
• Ensure that all drives in the
operating system drive slots are
correctly attached and do not
have data on them. Physical disks
for the operating system must be
of the same type and must meet
the minimum size requirements.
• Enter the PERC BIOS during the
operating system boot operation
and ensure that there are no
foreign configurations, drives are
clean of all data, the drives meet
the minimum size requirement,
and are fully functioning and
accessible. For more information,
see the PERC documentation at
support.dell.com/manuals.
To workaround this issue, enter the
PERC BIOS during the operating
system boot operation and ensure
that there are no foreign
configurations, drives are clean of
all data, the drives meet the
minimum size requirement, and
are fully functioning and
accessible. For more information,
see the PERC documentation at
support.dell.com/manuals.