Figure 1-29. SDLT Bent-In Leader Buckles
hooks
Media with bent-in leader buckles have been known to cause the tape drive to drop the leader
when the drive tries to load the media into the take-up reel.
Cartridge Storage
When storing cartridge, avoid moisture and direct sunlight. Exposure to moisture or sunlight
can deform or ruin media.
Table 1-6. Normal Storage Conditions (Nonarchival)
Temperature
• Between 61ºF and 90ºF (16ºC and 32ºC)
• Wet bulb temperature 78ºF (26ºC)
Table 1-7. Archival Storage Conditions (for one or more years)
Temperature
Between 64ºF and 79ºF (18ºC and 26ºC)
Relative Humidity
Between 20% and 80%
Relative Humidity
Between 40% and 60%