Dell Storage Center SCv2000 Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Lagerung Dell Storage Center SCv2000 herunter. Dell Storage Center SCv2000 42 Seiten. Storage center
Auch für Dell Storage Center SCv2000: Handbuch "Erste Schritte (19 seiten), Handbuch "Erste Schritte (20 seiten)

Dell Storage Center SCv2000 Benutzerhandbuch
SCv2000/SCv2020 Storage Controller with SAS Front-End Ports
Features and indictors on a storage controller with SAS front-end ports.
Figure 7. SCv2000/SCv2020 Storage Controller with Four 12 Gb SAS Front-End Ports
Item Control/Feature
1
Battery status indicator
2
Battery fault indicator
3
MGMT port
4
REPL port
5
SAS activity indicators
6
Storage controller
module status
7
Recessed power off
button
8
Storage controller
module fault
14
Icon Description
Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat
Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is
charging
Steady green: Battery is ready
Off: No faults
Blinking amber: Correctable fault detected
Steady amber: Uncorrectable fault detected; replace battery
10 Mbps, 100 Mbps, or 1 Gbps Ethernet port used for storage
system management and access to the BMC
NOTE: To use the MGMT port as an iSCSI port for
replication to another Storage Center, a Flex Port license
and replication license are required. To use the MGMT port
as a front-end connection to host servers, a Flex Port
license is required.
10 Mbps, 100 Mbps, or 1 Gbps Ethernet/iSCSI port used for
replication to another Storage Center
NOTE: To use the RELP port as a front-end connection to
host servers, a Flex Port license is required.
Off: Port is off
Steady green: Port is on, but without activity
Blinking green: Port is on and there is activity
On: Storage controller completed POST
Powers down the storage controller if held for more than five
seconds
Off: No faults
Steady amber: Firmware has detected an error
Blinking amber:Storage controller is performing POST
About the SCv2000/SCv2020 Storage System