Dell Storage Center SCv2020 Benutzerhandbuch - Seite 30
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Lagerung Dell Storage Center SCv2020 herunter. Dell Storage Center SCv2020 42 Seiten. Storage center
Auch für Dell Storage Center SCv2020: Handbuch "Erste Schritte (19 seiten), Handbuch "Erste Schritte (20 seiten)
![Dell Storage Center SCv2020 Benutzerhandbuch](/uploads/products/server2/3220860/3220860.png)
•
Controlling access to hard drives
•
Communicating storage attributes and states to the storage system
NOTE: Do not return the storage controller battery with the failed storage controller. A new battery
is not included with a replacement storage controller.
Identify the Failed Storage Controller
To determine which storage controller failed, use the Dell Storage Client .
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
storage controller.
Figure 23. Hardware Alert Identifying the Enclosure with the Failed Storage Controller
4.
In the Hardware tab navigation pane, expand the Enclosures entry.
5.
Click I/O Modules. The status of each storage controller is displayed in the I/O Modules tab.
6.
Select the failed storage controller to display its location in the IO Module View tab.
30
Replacing SCv2000/SCv2020 Components