Implementing FCoE in the Linux Operating System
6. Finally, to determine the device names for your FCoE LUNs, run the cat /proc/partitions
command, as in Figure 14. In this example, the FCoE LUNs are listed as /dev/sdb and
/dev/sdc .
Partition and mount FCoE LUNs as any other hard disk device.

Configure the FCoE client to start at boot

If you want the FCoE client to start and the FCoE LUNs to automatically be available after every
reboot, configure the appropriate services using YaST2 by performing the following steps:
1. Start the YaST2 Control Center using the yast command, select Network Service , and then
FCoE Client Configuration , as in Figure 15.
Figure 14.
FCoE LUNs displayed.
18