Addendum to the 32 48 and 5 224 User 's Guides
Forward Delay — The maximum time, in seconds, the switch waits
before changing states (such as, discarding to learning to forwarding).
This delay is required because every device must receive information
about topology changes before it starts to forward frames. In addition,
each port needs time to listen for conflicting information that would
make it return to a discarding state; otherwise, temporary data loops
might result.
Default: 15
Minimum: The higher of 4 or [(Max. Message Age / 2) + 1]
Maximum: 30
To save any changes you make in this page, click Apply Changes. If you do
not want to save the changes, click Refresh.