Dell PowerConnect PC7048R Anweisungen zum Stapeln - Seite 23
Blättern Sie online oder laden Sie pdf Anweisungen zum Stapeln für Schalter Dell PowerConnect PC7048R herunter. Dell PowerConnect PC7048R 37 Seiten. Stacking gigabit ethernet switches
Auch für Dell PowerConnect PC7048R: Technisches Weißbuch (34 seiten)
Stacking Dell PowerConnect 7000 Series Switches
Scenario 2
Consider the same example with a four-unit stack connected in daisy-chain fashion.
Stack Split
Figure 3.
If the link between Switch 2 and Switch 3 is removed, the stack is split into two different stacks with
Switches 1 and 2 in one stack and Switches 3 and 4 in another.
The Master unit for each stack is determined by the following criteria:
Switch 3 was configured as Master prior to the split, so it will continue to be the Master
unit for Stack 2 (units 3 and 4).
If Switch 2 is configured as the Standby, it becomes the Master for Stack 1 (units 1 and
2).
If none of the units in Stack 1 are configured as Master or Standby, then Stack 1 will
have no Master after the split. The election process will start on these two units, and
either Switch 1 or Switch 2 will come up as a master based on which switch has the
highest base MAC address.
In this specific example, there will not be any change in the configuration in Stack 2. Stack 1 will come
up with the previously saved configuration on the new Master elected.
Note that stack splits are less likely when the switches are cabled in a ring. For example, if Switch 4
was connected to Switch 1 and the link between Switch 2 and Switch 3 was removed, all switches
would remain members of the single stack with Switch 3 continuing as the Master.
Switch 1
Switch 2
Standby
Switch 3
Master
Switch 4
Standby
Stack 1
Switch 1
Switch 2
Master
Switch 3
Master
Switch 4
Stack 2
Page 21