System Descriptions

LUBRICATION

After the final test at the factory, the oil is removed from the
engine to comply with Federal shipping laws. Therefore, it is
necessary to put oil into the engine before attempting to start it.
The crankcase capacity is approximately 1.25 liters (1.33
quarts). The oil Dipstick has two marks on it (3/12). The upper
one is the "full" mark and the lower one indicates "add oil." The
distance between the two marks is equivalent to approximately
0.18 liters (0.19 quarts). NEVER, NEVER, overfill the engine.
The best operating condition will be with the oil level slightly
below the "full" mark.
The oil fill cap is located on the top of the gear cover (3/11).
There is no oil filter on this engine.
The American Petroleum Institute classifies oil according to
application. Within these classifications there are good, better,
and outstanding oils for use in small diesel engines. We recom-
mend a product marketed by Chevron Oil Co. called DELO-400.
We suggest a multi-viscosity 15W-40 weight for all season use.

ENGINE CONTROL SYSTEM

The remote run/stop control for the engine is accomplished
through the use of a special high pressure valve. When the valve
is energized, it closes and the injection pump is allowed to
deliver high pressure fuel to the injector. The engine is further
controlled by three switches: water temperature, exhaust tem-
perature, and oil pressure.
Water Temperature Switch. The water temperature switch
(12/47) is located on the cylinder head. It is normally closed and
will open when the engine coolant temperature rises to 185
degrees F. It will close again at approximately 160 degrees F.
Exhaust Temperature Switch. The exhaust temperature switch
(16/19) is located in the casting wall of the Exhaust Elbow. It is
normally closed and will open when the internal temperature of
the elbow rises to 185 degrees F. It will close again at approxi-
mately 160 degrees F.
Oil Pressure Switch. The oil pressure switch (2/5) is mounted
on the left side of the engine, looking at the handcrank end. It is
normally open and is set to close at 15 psi. It will open if the oil
pressure falls below 12 psi.
Entec West, Inc.
16710 SW 72nd • Portland, Oregon 97224 • (503) 624-7118
EW-4200D
Dipstick
Oil Fill Cap
Water Temperature Switch
Exhaust Temperature Switch
Oil Pressure Switch
7