Dell S60 System Handbuch - Seite 22
Blättern Sie online oder laden Sie pdf Handbuch für Schalter Dell S60 System herunter. Dell S60 System 45 Seiten.
Power Supplies
The S60 system is designed to support two hot-swappable power supply units (PSUs) with integrated
fans that provide the cooling for the system. There are two types of power supplies (AC or DC) and there
are two airflow directions (normal and reverse). Two PSUs are required for full redundancy, but the
system will operate with a single PSU. You can equip one of the PSU bays with a fan-only module.
For the procedure to replace only a fan module or fan filter, refer to
You can order the S60 system as an empty chassis or with either AC power
(Figure
4-2). Both PSU types are field replaceable. When running with full redundancy (two PSUs
installed and running), you can remove and replace one PSU while the other PSU is running without
disrupting traffic.
WARNING: To prevent electrical shock, ensure the S60 system is grounded properly. If you do not ground
your system correctly, excessive emissions may result. Use a qualified electrician to ensure that the power
cables meet your local electrical requirements.
WARNING: Electrostatic discharge (ESD) damage can occur if the components are mishandled. Always
wear an ESD-preventive wrist or heel ground strap when handling the S60 system and its components.
Components
The following power supply options are available for the S60 system:
• AC power supply with integrated fans
• AC power supply with integrated reverse flow fans
• DC power supply with integrated fans
• DC power supply with integrated reverse flow fans
Figure 4-1. AC Power Supply
PSU0
Securing Screw
PSU1
Grab Handle
Chapter 5, Fans and
(Figure
4-1) or DC power
Fans and Filters
AC Power Connector
4
Filters.
Power Supplies
|
22