Dell Z9100-ON Installationshandbuch - Seite 28

Blättern Sie online oder laden Sie pdf Installationshandbuch für Schalter Dell Z9100-ON herunter. Dell Z9100-ON 43 Seiten. Open networking
Auch für Dell Z9100-ON: Installationshandbuch (45 seiten), Installationshandbuch (45 seiten)

Dell Z9100-ON Installationshandbuch
Figure 13. Z9100–ON Fan Modules
1.
Fan Modules

Installing a Fan Module

The fan modules in the Z9100–ON are field replaceable.
Module slot 1 is on the left side of the chassis, module slot 2 is in the middle of the chassis, and module
slot 3 is on the right side of the chassis.
CAUTION: DO NOT mix airflow directions. All fans must use the same airflow direction (reverse or
normal). If you mix the airflow direction, the switch detects the discrepancy, issues an alarm, and
may auto-shutdown to avoid heat damage to components. You must correct the mixed airflow
direction.
To install a fan module, follow these steps.
1.
Take the fan module out of the shipping box.
2.
Slide the module into the bay.
Figure 14. Installing the PSU and Fan
Power supply unit on the right
Fan unit on the left
28
Fans