Miele PW 6101 Programmieranleitung Handbuch - Seite 23
Blättern Sie online oder laden Sie pdf Programmieranleitung Handbuch für Waschmaschine Miele PW 6101 herunter. Miele PW 6101 48 Seiten. Profitronic m innovation m
Auch für Miele PW 6101: Betriebsanleitung (44 seiten), Betriebsanleitung (46 seiten), Programmieranleitung Handbuch (48 seiten)
10. Water inlet 1
Selection choice:
– Automatic
If the water inlet valves are programmed to
"automatic" the required wash temperature is
achieved during the water intake by
controlling the cold and hot water inlet
valves.
The water inlet valves in the dispenser
drawer compartments are set as follows:
Pre-wash compartment
Main wash compartment
Fabric conditioner compartment
Additional agent compartment
Direct water intake
WRG inlet valve (Water recycling)
The following inlet valves are controlled
according to programme block:
Programme
Actual
sequence
temp. >
Rqrd.
Pre-wash 1
KD, K1
Pre-wash 2-10
KD, K1
Main wash 1
KD, K2
Main wash 1-10
KD, K2
(with pre-wash)
Rinse 1
KD, K3
Rinse 1
KD,K4
Rinse 2
KD, K3
Rinse 1
KD
Rinse 2
KD,K4
Rinse 3
KD, K3
Rinse 1
KD
Rinse 2
KD,K4
Rinse 3-9
KD
Rinse 10
KD,K3
M.-Nr. 06 533 430
Inlet valve
K1, W1
K2, W2
K3
K4
KD, WD
K6
Temperature area
Actual
Actual
temp. =
temp. <
Rqrd.
Rqrd.
WD, W1,
WD, W1,
KD, K1
KD, K1
WD, KD,
WD, W1
K1
WD, W2,
WD, W2,
KD, K2
KD, K2
KD, WD,
WD, W2
W2, K2
KD, WD,
WD, K3
K3
KD,WD,K4 WD,K4
KD, WD,
WD, K3
K3
KD, WD
WD
KD,WD,K4 WD,K4
KD, WD,
WD, K3
K3
KD, WD
WD
KD,WD,K4 WD,K4
KD, WD
WD
KD,WD,
WD,K3
K3
– User defined
No
4 of 10 different inlet valves
The optimum hot water intake may not
always take place. However the actual
temperature will never be higher than the
required temperature. The controls will react
beforehand to bring in a different inlet valve.
Actual temp. >
Water valve
W1 -> K1
Water valve
W2 -> K2
Water valve
WD -> KD
11. Dispensing method
This stipulates how the agents are
dispensed into the machine.
Selection choice:
– No
No dispensing takes place
– Amount in ml (millilitre)
– Concentration in ml/l (millilitre per litre)
This does not appear when programming
the programme header for fill type "water
level", "auto load control"
– Concentration ml/kg (millilitre per load of
laundry in kg)
Programming
Temperature area
Actual temp. =
Rqrd.
Rqrd.
W1, K1
W2, K2
WD, KD
23