Miele PW 6101 Programmieranleitung Handbuch - Seite 25
Blättern Sie online oder laden Sie pdf Programmieranleitung Handbuch für Waschmaschine Miele PW 6101 herunter. Miele PW 6101 48 Seiten. Profitronic m innovation m
Auch für Miele PW 6101: Betriebsanleitung (44 seiten), Betriebsanleitung (46 seiten), Programmieranleitung Handbuch (48 seiten)
15. Water level stop 1
Selection choice:
– No
Water is taken in at the right time into the
following programme stages: Dispensing
phase 1 and 2, Agitation from level and
Wash time 1 and 2. These programme steps
take place at the same time as the water
intake.
– Yes
First water is taken into the machine up to
the level specified and then the following
programme steps are carried out. The
programme stops whilst water is being taken
into the machine. Drum rotation is controlled
via the "Agitation from level" function.
16. Wash time 1
During the time specified the drum will rotate
using the rhythm specified and at the spin
speed set.
Selection choice:
– No
– User defined
Time
0, 15 to 59 sec
0 to 99 min.
Rhythm
No
Normal
Gentle
Gentle+
User defined
On: 2 to 99 sec.
Off: 2 to 99 sec.
Spin speed
No
Normal
Drench
User defined
20 to 70 rpm.
M.-Nr. 06 533 430
17. Thermo stop
$ Thermo stop locked if programme step 4.
Heating is programmed to "No".
Selection choice:
– No
If the Thermo stop has been set to "No" the
heating phase will start when the minimum
heating level is reached. Wash times 1 and 2
will be carried out on a timed basis without
necessarily reaching the temperature
selected.
– Yes
If the Thermo stop has been set to "Yes" the
heating phase will also start when the
minimum heating level is reached. However
wash time 2 will not start until the required
temperature has been reached. Wash time 2
always starts with the required temperature.
– Disinfection
If the Thermo stop has been programmed to
"Disinfection" the same conditions apply as
for Thermo stop "Yes". However if a
temperature has not been maintained to
within 3°C of the permitted hysteresis value,
e.g. because of a peak-load or a mains
interruption, then then the machine will go
into Thermo stop again and wash time 2 and
dispensing phase 2 will have to be carried
out again.
18. Water level 2
Settings as for Water level 1
19. Water inlet 2
Settings as for Water inlet 1
20. Dispensing phase 2
Settings as for Dispensing phase 1
21. Dispensing stop 2
Settings as for Dispensing stop 1
Programming
25