Miele PW 6163 Betriebsanleitung - Seite 43
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Waschmaschine Miele PW 6163 herunter. Miele PW 6163 46 Seiten.
Dispenser system connections
Connections 1 and 2 are for viscous agents
only. These connections are sealed and
have to be drilled open with an 8 mm drill
bit.
Only drill through the first wall. A second one
is located 10 mm behind it to deflect the
agent.
Any connections that have been drilled open
must be resealed if they are subsequently
not required.
Connections 3 to 12 are for liquid agents
only. These connections are also sealed and
have to trimmed to the correct diameter for
the hoses being used with a suitable small
saw.
Any connections that have been opened
must be resealed if they are subsequently
not required.
Notes for the installer
Electrical connection
The electrical connection must only be
carried out by a suitably qualified electrician
in accordance with local and national safety
regulations (BS 7671 in the UK).
When installing a residual current device
(RCD), this must be a Type B RCD (suitable
to detect high frequency AC and DC earth
leakage current).
Connection should be made in accordance
with the wiring diagram and the installation
diagram to a suitable isolator, with an on-off
switch which is easily accessible for
servicing. The wiring and installation
diagrams are important for the correct
electrical functioning of the machine.
The electrical components on the PW 6163,
PW 6243 and PW 6323 machines conform to
EN 60204.
The connection points are located behind a
cover. The mains cable should be fed
through the core to the connection clamps.
The machine is supplied ex-works for 3N AC
50-60 Hz. See data plate for details.
It is also available in the following
versions:
3 N AC 380-415 V 50-60 Hz
3 AC 220-240 V 50-60 Hz
43