Allmand Nite Lite V Series Gebrauchsanweisung - Seite 11
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Tragbarer Generator Allmand Nite Lite V Series herunter. Allmand Nite Lite V Series 17 Seiten.
![Allmand Nite Lite V Series Gebrauchsanweisung](/uploads/products/server2/340909/340909.jpg)
SERIAL NUMBER 39-000001 AND UP
● Example M:
● If the previous procedure indicates proper voltage at the top (input)
terminals of the main breaker, test the voltage at the bottom (output) main
breaker terminals (See Example "D" and Example "B"). The meter reading
should indicate 120 volts + 10%. If the reading of 120 Volts +10% is not
measured at each terminal, the main breaker is faulty and must be
replaced. Contact Allmand Parts Department (308-995-4495) for the
correct replacement circuit breaker.
Nite Lite V Series
11