Allmatic ACTION Anweisungen für die Installation
Blättern Sie online oder laden Sie pdf Anweisungen für die Installation für Kontrolleinheit Allmatic ACTION herunter. Allmatic ACTION 5 Seiten. For tecno-cat
1. Introduction
Action is a control unit dedicated to the movement of the chain barrier with 24Vdc motor. The coexistance of various types of safeties such as the con-
trol of the absorbed power by the motor and the velocity of the motor allows a rapid intervention of the anti – squeezing security (sense). Through the
encoder present in the motor it is possible to control the exact position of the chain and to use it without mechanical limit switches. The control unit has
inputs for mechanical limit switches, for the step by step button, for the pedestrian opening, for the safety photocells and the output for flashing light 24
Vac. The unit also allows the regulation by trimmer both the automatic re-closure and the motor force. Action can control motors at 24 – 30 Vcc with a
maximum consumption of 7A.
2. Configuration
Use this point to connect
the motor's casing to the
control panel and to the
ground.
Jumper ( if present)
in order to invert the
motor phases
Connector for the
battery charger.
24Vac Power supply
3. Electrical connections
Terminal
Function
1 – 2
Flashing signal output
3
Positive power supply TX & RX photocell
4
Negative power supply TX photocell
5
Negative power supply RX photocell and
common button and safety
6
Stop closure button input
7
Stop open button input
8
STOP button input
9
RX photocell contact input
10
Pedestrian button input
11
Relay button input
12
Antenna screen input
13
Antenna input
IMPORTANT: to obtain a correct working of the accessories (photo devices in particular) connected to the control box, it is very important that the
entire system (motor+ control box) has a single mass reference system. You must therefore connect a small cable between the motor casing and the
control box at the point shown in the figure. If there is a good ground connection it is advisable to connect it to the system.
6-1622349 rev.3 28/03/2019
ACTION CONTROL UNIT for Tecno-cat
INSTRUCTIONS FOR INSTALLATION
Automatic
re-closure
Courtesy light
Motor/ Encoder Connector
Setting
OUT: 24 Vac 25 W MAX
OUT: +24Vcc
OUT: GND TX
OUT: GND RX
Common
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally open (NO)
Normally open (NO)
GND
Antenna
Any contact which is
Normally Closed (N.C.)
Must be bridged to the
common if not used.
5
6
ITA
ENG
Photocells
Power supply
A
B
7
8
9 10
Note: Cable colours valid only for Tecno-cat motor.
FRA
ESP
DEU
POR
Setting maximum
torque threshold.
Radio connector
Buttons:
1 = yellow
2 = Blue
3 = Red
Manual selector (Left) /
automatic (Right).
Motor/ Encoder Connector.
C
D
E
Encoder +5Vcc (brown)
Signal (green)
GND (white)
Motor