Cleaning and care
Cleaning the grease filters by hand
 Clean the filters with a soft nylon
brush in a mild solution of hot water
and a small amount of washing-up
liquid. Do not use undiluted washing
up liquid.
Unsuitable cleaning agents
Unsuitable cleaning agents can cause
damage to the surface of the filters if
used regularly.
Do not use:
– cleaning agents containing descaling
agents,
– powder cleaners or cream cleaners,
– aggressive all-purpose cleaning
agents or spray cleaners for grease,
– oven sprays.
Cleaning the grease filters in the
dishwasher
 Place the filters as upright as possible
in the lower basket, with the short
sides upright, ensuring the spray arm
is not obstructed.
 Use a proprietary household
dishwasher detergent.
 Select a dishwasher programme with
a wash temperature between 50 °C
and 65 °C.
Depending on the cleaning agent
used, cleaning the filters in a
dishwasher can cause permanent
discolouration to the surface.
However, this will not affect the
functioning of the filters in any way.
20
After cleaning
 After cleaning, leave the filters to dry
on an absorbent surface before
refitting them.
 When removing the filters for
cleaning, also clean off any residues
of oil or fat from the now accessible
housing to prevent the risk of these
catching fire.
 Replace the grease filters, making
sure that the locking clips are facing
down towards the cooktop.
 If a grease filter is inadvertently
refitted upside down, insert a small
screwdriver blade into the slit to