Miele DA 189 Betriebs- und Installationsanleitung - Seite 10

Blättern Sie online oder laden Sie pdf Betriebs- und Installationsanleitung für Lüftungshaube Miele DA 189 herunter. Miele DA 189 28 Seiten. Miele ventilation hood user manual

Miele DA 189 Betriebs- und Installationsanleitung

Operation

The range hood operates
. . . in air extraction mode:
The air is drawn in and cleaned by the
grease filters and then directed outside.
If your air extraction system does not
have a non-return flap, one is
provided with the range hood.
A non-return flap in the ventilation
system ensures that when the range
hood is shut off no unwanted exchange
can occur between room air and
outdoor air.
It is closed when the range hood is shut
off.
When the hood is switched on, the
non-return flap opens so that the
exhaust air can be transported
unimpeded to the outside.
10
. . . in air recirculation mode:
The air drawn in is cleaned by the
grease filters and then by two
deodorizing filters.
The air is returned to the kitchen
through an opening in the top of the
range hood.
The deodorizing filters are available as
accessories (see "Technical data").
In recirculation operation, ensure that
the deodorizing filters are in place; see
"Care and Cleaning".