Installation
Safety distance between hob and
cooker hood (S)
The following minimum safety
distance must be maintained
between the top of the cooker/hob
and the bottom of the cooker hood
unless a greater distance is
specified by the manufacturer of the
cooker or hob:
Cooking appliance
Electric hob
Open Grill
Deep fat fryer (electric)
Multi-burner gas hob with
a maximum total output of
12.6 kW, no burner
exceeding 4.5 kW.
Multi-burner gas hob with
a total output of more than
12.6 kW, or a multi-burner
gas hob where one burner
exceeds 4.5 kW.
Single gas burner with a
maximum output of 6 kW.
Single gas burner with
output exceeding 6 kW.
See "Warning and Safety"
instructions for further information.
28
– However, we recommend a minimum
distance of 700 mm and a maximum
distance of 1300 mm.
Please be aware that if positioned too
high, extraction will be inefficient.
Distance
S
450 mm
650 mm
650 mm
650 mm
760 mm
The cooker hood must cover the hob to
ensure optimum extraction of cooking
vapours:
– The cooker hood should be
positioned centrally over the hob, not
650 mm
offset to one side or to the rear.
– The hob should be smaller than the
760 mm
cooker hood if possible, and no
larger than equal size.